DETECTOR
APIR4
DUAL INFRA-RED DETECTOR FOR OUTDOOR USE VIA RADIO
Technical features
- Power supply: 3 Volts (2 x 1.5 V AA or LR6 alkaline batteries)
- Absorption in standby: 25 µA
- Coverage: 12m x 80°, 9 zones on 1 plane for each lens
- Transmission frequency: 433.42 / 434.42 MHz
- TX module power: 10 mW
- Operating temperature: -15° to +50°C
- Dimensions: 165 x 50 x 84 mm
- Housing: Protection Grade IP 55
“AWACS Platinum” range advanced-technology microprocessor-controlled dual infra-red wireless detector, typically used for the external protection of balconies, verandas, covered sites, or for internal protection of industrial facilities, loading bays, stairwells, etc. Typical range 12 m, detection over 80° on a two planes with 9 sensitive zones, possibility of orienting the lens detection angle (bars from 1 to 5). The alarm condition occurs when both lenses are affected by the event. Sensitivity can be selected on 4 levels (DIP2/DIP3). Using the DIP switch settings the anti-masking feature of the IR sections can be enabled (DIP4) as well as the impact and tamper feature (DIP5) and the sensitivity (DIP7), analysis time from the first event can be adjusted from 2 to 4 seconds (DIP5). An impact sensitivity test can be carried out and the installer can select infra-red double or single edge (DIP9) as well as conduct a combined test of the two IR sections (DIP1).
To limit battery consumption, after each transmission there is a 2 minute cut-off time; low battery signal at 2.6 V. IR sensitivity temperature compensation. Should the sensor be wall mounted, one of the anchoring points (top right) acts as a removal tamper and the TAMPER transmission is sent. Housing in impact and UV ray resistant material. This type of detector must be installed at a height of 1 metre with AA 1.2 GI V2 type lenses.
Request for further information on APIR4
Do you want to receive more information on this product? Fill out the form below and our staff will get back to you as soon as possible.